• Sperm DNA Fragmentation Test Kit AOT Flow Cell Methodology
  • Sperm DNA Fragmentation Test Kit AOT Flow Cell Methodology
Sperm DNA Fragmentation Test Kit AOT Flow Cell Methodology

Sperm DNA Fragmentation Test Kit AOT Flow Cell Methodology

Szczegóły Produktu:

Miejsce pochodzenia: Chiny
Nazwa handlowa: BRED
Orzecznictwo: CE, ISO13485, CFDA
Numer modelu: BRED-029

Zapłata:

Minimalne zamówienie: 1 zestawy
Cena: Zbywalny
Szczegóły pakowania: 20T/zestaw
Czas dostawy: 3-5 dni roboczych
Zasady płatności: T/t,
Możliwość Supply: 10000 zestawów rocznie
Najlepsza cena Kontakt

Szczegóły informacji

Okres przydatności do spożycia: 12 miesięcy Temperatura przechowywania: 2 - 8 ℃
Specyfikacja: 20T / zestaw Metoda testowa: Metodologia komórek AOT Flow
Podkreślić:

male infertility test kit

,

papanicolaou stain kit

opis produktu

Sperm Chromatin Structure Assay Kit DNA Fragmentation Diagnosis

AOT Flow Cell Methodology

 

 

After denatured by acid, fragmented sperm chromatin would turn to single strand. And the normal sperm chromatin retain double strand. Acridine Orange(AO) associated with single-stranded DNA emits red or yellow fluorescence at 488nm luminescence. While AO intercalated in double stranded DNA emits green fluorescene. If the red fluorescence is increasing, it shows a high rate of DNA fragmentation in sperms.

 

Packing specification: 

  • 20 tests/kit

Intended use:

  • The kit is designed to evaluate the DNA integrity and maturity of human sperm by staining sperm chromatin.

Main compositions:

Storage conditions and duration:

  • Storage conditions: The kit is kept at 2 ~ 8 ℃ in dark place.
  • Period of validity: The kit is kept at 2 ~ 8 ℃ for one year. After dissolved, the reagent C would be kept for two weeks in dark at 2 ~ 8 ℃. Once separately store the dissolved reagent C at -20 ℃ in dark, the use life of reagent C could be more than one year.

Applicable instrument:

  • Flow cytometer (488nm luminescence)

Specimen requirements:

  • The sample should be collected after a minimum of 48 hours but not longer than seven days of sexual abstinency by masturbation or sexual intercourse using special condoms. The semen sample must be complete in collection.
  • Fresh semen samples should be liquefied completely prior to testing. If the samples have delayed liquefaction or high viscosity, a liquefier (sold separately) should be conducted.

Sperm DNA Fragmentation Test Kit AOT Flow Cell Methodology 0

Chcesz dowiedzieć się więcej o tym produkcie
Jestem zainteresowany Sperm DNA Fragmentation Test Kit AOT Flow Cell Methodology czy mógłbyś przesłać mi więcej informacji, takich jak rodzaj, rozmiar, ilość, materiał itp.
Dzięki!
Czekam na Twoją odpowiedź.